1. Factored Axial Loads and Bending Moments

1.1. Service loads

Table 2 - Exterior column service loads

Load Case

Axial Load, kN

Bending Moment, kN-m

Top

Bottom

Dead, D

1,615.2

107.36

118.00

Live, L

362.86

67.43

72.86

Wind, W

0

90.19

105.33

1.2. Load Combinations - Factored Loads

CSA A23.3-19 (Annex C, Table C.1a)

Table 3 - Exterior column factored loads

CSA A23.3-19

Reference

No.

Load Combination

Axial Load, kN

Bending Moment, kN-m

MTop,ns

kN-m

MBottom,ns

kN-m

MTop,s

kN-m

MBottom,s

kN-m

Top

Bottom

Annex C

Table C.1a

1

1.4D

2,261

150.3

165.2

150.3

165.2

0.0

0.0

2

1.25D + 1.5L

2,563

235.3

256.8

235.3

256.8

0.0

0.0

3

1.25D + 1.5L + 0.4W

2,563

271.4

298.9

235.3

256.8

36.1

42.1

4

1.25D + 1.5L - 0.4W

2,563

199.3

214.7

235.3

256.8

-36.1

-42.1

5

0.9D + 1.5L + 0.4W

1,998

233.8

257.6

197.8

215.5

36.1

42.1

6

0.9D + 1.5L - 0.4W

1,998

161.7

173.4

197.8

215.5

-36.1

-42.1

7

1.25D + 0.5L + 1.4W

2,200

294.2

331.4

167.9

183.9

126.3

147.5

8

1.25D + 0.5L - 1.4W

2,200

41.6

36.5

167.9

183.9

-126.3

-147.5

9

0.9D + 0.5L + 1.4W

1,635

256.6

290.1

130.3

142.6

126.3

147.5

10

0.9D + 0.5L - 1.4W

1,635

4.1

-4.8

130.3

142.6

-126.3

-147.5