4. Two-Way Slab Shear Strength
Shear strength of the slab in the vicinity of columns/supports includes an evaluation of one-way shear (beam action) and two-way shear (punching) in accordance with ACI 318 Chapter 22.
4.1. One-Way (Beam Action) Shear Strength
One-way shear is critical at a distance d from the face of the column. Figure 16 shows the Vu at the critical sections around each column. Since there is no shear reinforcement, the design shear capacity of the section equals to the design shear capacity of the concrete:
| ACI 318-14 (Eq. 22.5.1.1) |
Where: | |
| ACI 318-14 (Eq. 22.5.5.1) |
λ = 1 for normal weight concrete | |
Because ϕVc > Vu at all the critical section, the slab is o.k. in one-way shear. |
Figure 16 – One-way shear at critical sections (at distance d from the face of the supporting column)
4.2. Two-Way (Punching) Shear Strength
Two-way shear is critical on a rectangular section located at dslab/2 away from the face of the column. The factored shear force Vu in the critical section is calculated as the reaction at the centroid of the critical section minus the self-weight and any superimposed surface dead and live load acting within the critical section.
The factored unbalanced moment used for shear transfer, Munb, is calculated as the sum of the joint moments to the left and right. Moment of the vertical reaction with respect to the centroid of the critical section is also taken into account.
For the Exterior column:
Figure 17 – Critical Section of Exterior support of Interior Frame
For the exterior column in Figure above the location of the centroidal axis z-z is:
The polar moment Jc of the shear perimeter is:
ACI 318-14 (Eq. 8.4.4.2.2) | ||
Where: | ||
ACI 318-14 (8.4.2.3.2) | ||
| ||
The length of the critical perimeter for the exterior column: | ||
The two-way shear stress (vu) can then be calculated as: | ||
ACI 318-14 (R.8.4.4.2.3) | ||
| ||
ACI 318-14 (Table 22.6.5.2) | ||
Because ϕvc ≥ vu at the critical section, the slab has adequate two-way shear strength at this joint. |
For the Interior Column:
Figure 18 – Critical Section of Interior support of Interior Frame
For the interior column in Figure above the location of the centroidal axis z-z is:
The polar moment Jc of the shear perimeter is:
ACI 318-14 (Eq. 8.4.4.2.2) | ||
Where: | ||
ACI 318-14 (8.4.2.3.2) | ||
| ||
The length of the critical perimeter for the exterior column: | ||
The two-way shear stress (vu) can then be calculated as: | ||
ACI 318-14 (R.8.4.4.2.3) | ||
| ||
ACI 318-14 (Table 22.6.5.2) | ||
Because ϕvc ≥ vu at the critical section, the slab has adequate two-way shear strength at this joint. |